Specifications

18
Once the array is added successfully, the Protection Arrays section at the bottom of the screen
will indicate the replicated storage is properly detected.
5. After finishing the configuration dialogs, the Review Mirrored LUNs page will indicate all the discovered
NetApp LUNs containing ESX datastores and their associated replication targets. Click Finish.
6. The array managers must also be configured at the DR site. The adapters are added to array managers
in the same manner as above, however the arrays should be added in reverse order. In this SRM server
the array at the DR site is considered the protected array, and the array at the primary site is considered
the recovery array. In this case there might be no storage being replicated from this site to the other
site. So the final screen of the configure array managers wizard might show an error or warning
indication that no replicated storage was found. This is normal for a one-way SRM configuration.