Table 73. MSI Properties for Silently Installing a Security Server (Continued)
MSI Property Description Default Value
FWCHOICE The MSI property that determines whether to configure a firewall for
the View Connection Server instance.
A value of 1 configures a firewall. A value of 2 does not configure a
firewall.
For example: FWCHOICE=1
This MSI property is optional.
1
VDM_SERVER_SS_PCOIP_IP
ADDR
The PCoIP Secure Gateway external IP address. In an IPv6 environment,
this property can also be set to the FQDN of the PCoIP Secure Gateway.
This property is supported only when the security server is installed on
Windows Server 2008 R2 or later.
For example: VDM_SERVER_SS_PCOIP_IPADDR=10.20.30.40
This property is required if you plan to use the PCoIP Secure Gateway
component.
None
VDM_SERVER_SS_PCOIP_T
CPPORT
The PCoIP Secure Gateway external TCP port number. This property is
supported only when the security server is installed on Windows Server
2008 R2 or later.
For example: VDM_SERVER_SS_PCOIP_TCPPORT=4172
This property is required if you plan to use the PCoIP Secure Gateway
component.
None
VDM_SERVER_SS_PCOIP_U
DPPORT
The PCoIP Secure Gateway external UDP port number. This property is
supported only when the security server is installed on Windows Server
2008 R2 or later.
For example: VDM_SERVER_SS_PCOIP_UDPPORT=4172
This property is required if you plan to use the PCoIP Secure Gateway
component.
None
VDM_SERVER_SS_BSG_EXT
URL
The Blast Secure Gateway external URL. The URL must contain the
HTTPS protocol, an externally resolvable security server name, and port
number
For example:
VDM_SERVER_SS_BSG_EXTURL=https://view.companydomain.com:
8443
The default port number is 8443. A Blast Secure Gateway must be
installed on the security server to allow users to make Web connections
to View desktops.
None
VDM_SERVER_SS_FORCE_I
PSEC
Forces IPsec to be used between the security server and its paired View
Connection Server instance.
By default, an unattended installation and pairing of security server to a
View Connection Server instance with IPsec disabled causes the pairing
to fail.
The default value of 1 forces IPsec pairing. Set this value to 0 to allow
pairing without IPsec.
1
VDM_IP_PROTOCOL_USAG
E
Specifies the IP version that View components use for communication.
The possible values are IPv4 and IPv6
IPv4
VDM_FIPS_ENABLED Specifies whether to enable or disable FIPS mode. A value of 1 enables
FIPS mode. A value of 0 disables FIPS mode. If this property is set to 1
and Windows is not in FIPS mode, the installer will abort.
0