M5000 Series: User Guide
Switches and Jumper Settings
PCI-to-VME Bridge
The PCI-to-VME bridge is configured using the switches SW5, SW3 and SW11.
TABLE 2-3. PCI-to-VME bridge SW11 settings
Switch Function
1 SYSFAIL Assertion
SYSFAIL is not asserted when the switch is ON.
SYSFAIL is asserted asserted when the switch is OFF
2 VME64 AutoId
AutoId is enabled when the switch is ON
AutoId is disabled when the switch is OFF
TABLE 2-4. PCI-to-VME bridge SW5 settings
Switch Function
1-8 VME CS/CSR Base Address
Switches [1-8] are connected to VME addresses A[28-21].
Use 0x00 for AutoId
TABLE 2-5. PCI-to-VME bridge SW3 settings
Switch Function
1-2 VME CR/CSR Address Space
Switches [2-1] are connected to VME addresses A[30-29]
A24/AutoId is selected when switches [2-1] are [OFF, ON]
A16 is selected when switches [2-1] are both OFF
A32 is selected when switches [2-1] both [ON, OFF]
3 VME CR/CSR Enable
ON enables CR/CSR.
4 Board Reset to VME Reset Propagation
OFF allows the propagation from the board reset to the VME reset.