Service manual
S ECTION 5 – REPLACING COMPONENTS
CAFFÈ MIO – OPERATION AND SERVICE Page 68 of 110
Replacing Major Components
Temperature Probe
1. Switch the machine power OFF, and open the front and inner doors.
2. Disconnect the temperature probe from the “WATER TEMP” connector on the rear board.
3. Lift the machine lid open.
4. Remove the water tank access panel.
a) Remove the screw securing the front of the cover to the top of the machine.
b) Lift the front of the cover and disconnect the ground wire from the cover.
5. Pull the temperature probe out of the grommet on the tank top.
Temp. Probe Harness
Temperature Probe
Grommet
Pull out of Grommet