SECTION 4 - TROUBLESHOOTING
CAFFÈ MIO OPERATION AND SERVICE Page 38 of 110
Troubleshooting
Brewer Overflow
Water setting may be too high reduce the water setting.
Bottom pause setting may need to be increased.
Coffee setting may be too high reduce the coffee setting.
Coffee may be stale or not within specifications replace coffee.
Water temperature may be too high reduce the temperature.
Screen assembly may be dirty and clogged clean or replace the brewer screen
assembly
(P/N - K310306).
Screen assembly may be damaged replace screen assembly
(P/N - K310306).
Brew chamber may be cracked creating a vacuum loss replace chamber
(P/N -
M044065)
.
Cylinder may be scored or cracked creating a vacuum loss replace cylinder
(P/N -
M044071)
.
Teflon seal on piston may be worn replace Teflon seal
(P/N - K110174).
Water Tank
Boiling /Overfilling
Clean and dry the overflow cup.
The equipment may have been moved or bumped.
If water tank is overfilling, check the following;
o Water level probes may require cleaning.
o Water level probe harness may be defective replace the probe harness.
o Inlet valve may be leaking replace inlet valve
(P/N - E310018).
If water tank is boiling over, check the following;
o Water temperature setting may be too high reduce temperature setting.
o Temperature probe may be defective replace the probe
(P/N - M210220).
o Components inside water tank may be covered with scale delime water tank.
o Verify the wiring and connections to the water tank.
Not Heating
The overflow cup may be full of liquid clean and dry the overflow cup.
15 amp fuse may be blown replace the fuse
(P/N - M018046).
Thermal cut-off switch may be tripped press the small button in the center of the
thermal cutoff switch to reset.
If thermal cutoff switch trips with a full water tank, replace the thermal cutoff switch
(P/N - A210087)
.
Verify the wiring and connections to the water tank.
Check for power to the heater element. If power is present, replace the heater
element
(P/N - E310016).
The heater relay may be defective replace the heater relay
(P/N - M018R08).
Temperature probe may be defective replace the temperature probe
(P/N -
M210220)
.