Service manual

SECTION 4 - TROUBLESHOOTING
CAFFÈ MIO OPERATION AND SERVICE Page 37 of 110
Troubleshooting
Fuses
5 Amp Fuse Blowing
If fuse blows when machine is powered-up, check the following;
o Exhaust fan
o Front board
o Rear board
o Wiring
If fuse blows when a
COFFEE is brewed, check the following;
o Coffee valve
o Coffee dispenser motor
o Brewer motor
o Inlet valve
o Wiring
If fuse blows when a
CHOCOLATE is brewed, check the following;
o Whipper motor and/or transformer
o Chocolate dispenser motor
o Chocolate valve
o Inlet valve
o Wiring
15 Amp Fuse Blowing
Verify the wiring to the high-power components of the water tank.
Make certain all wiring terminals are pushed completely onto the tabs of the high-
power components.
Replace any damaged or burnt wiring terminals on high-power components.
Heater element may be damaged replace heater element
(P/N - E310016).
Heater relay may be defective replace heater relay
(P/N - M018R08).
Check the wiring inside the fuse box and on the 15 amp fuse holder
(P/N - E110114)
repair or replace any damaged components.
Overflows
Cup Tray Overflow
The cup tray may be full of liquid clean and dry the catch.
The
HOT WATER” valve may be leaking repair or replace the valve (P/N - M029082).
The
CHOCOLATE valve may be leaking repair or replace the valve (P/N - M029082).
Check the brewer home position if the piston stops below the pour spout creating
constant dripping after each cup, correct the home position by adjusting the brewer
HOME switch (P/N - M019399).
If no overflow is present, the rear board may be wet thoroughly dry or replace the
rear board
(P/N - G410232MIO).
Water Tank Overflow
The overflow cup may be full of liquid clean and dry the cup.
Equipment may have been moved, causing water to spill out of the water tank.
Water tank may be boiling over reduce the water temperature.
Water level probes may require cleaning.
Water level probes may not be pushed completely into the grommets adjust the
probes.
Inlet valve may be leaking replace the inlet valve
(P/N - E310309).