Specifications

Operation Manual Eccellenza Pod
33
MESSAGE DISPLAYED CAUSE POSSIBLE REMEDIES
Overheat Error
The water tank is
overheating.
Check the temperature settings in the
set-up.
The temperature probe may need to be
replaced.
Power Saving Mode
Press Start to Exit
The machine is in Power
Saving Mode.
Press "START" (
) to exit Power Saving
Mode.
Tank Not Heating Error
The hot water tank is not
heating.
Check the 15 amp fuse.
Reset the thermal cut-off switch.
Verify wiring to heater element.
Check heater element.
Temperature Probe
Error
The temperature probe is
not functioning correctly.
Replace the temperature probe.
Thermister Shorted
Error
The thermister is not
functioning correctly.
Replace the thermister.
Thermister Open Error
The thermister is not
functioning correctly.
Replace the thermister.
Water Level Error
The water tank is
overfilling.
Clean the water level probes.
The water temperature may be too high
lower the temperature.
Inlet valve may be leaking replace inlet
valve.
Water Source Error
The water tank is not filling
with water.
At this point, the water tank is not full
and this message has to be reset. To reset
it, switch the power off and on.
If the problem persists, check all
components on the water line (water filter,
tubing, fittings, etc.).
Check inlet valve to make certain it is
functioning properly.
In the case of a temporary disruption
with the water supply, the coffee maker will
reset itself after every hour.
Whipper Error
An error has been detected
with the whipper.
The whipper motor may be jammed.
Clean the whipper assembly.
Verify wiring to the whipper assembly.
The whipper motor assembly may need
to be replaced.