Specifications
Operation Manual Eccellenza Pod
33
MESSAGE DISPLAYED CAUSE POSSIBLE REMEDIES
Overheat Error
The water tank is
overheating.
• Check the temperature settings in the
set-up.
• The temperature probe may need to be
replaced.
Power Saving Mode –
Press Start to Exit
The machine is in Power
Saving Mode.
• Press "START" (
) to exit Power Saving
Mode.
Tank Not Heating Error
The hot water tank is not
heating.
• Check the 15 amp fuse.
• Reset the thermal cut-off switch.
• Verify wiring to heater element.
• Check heater element.
Temperature Probe
Error
The temperature probe is
not functioning correctly.
• Replace the temperature probe.
Thermister Shorted
Error
The thermister is not
functioning correctly.
• Replace the thermister.
Thermister Open Error
The thermister is not
functioning correctly.
• Replace the thermister.
Water Level Error
The water tank is
overfilling.
• Clean the water level probes.
• The water temperature may be too high
– lower the temperature.
• Inlet valve may be leaking – replace inlet
valve.
Water Source Error
The water tank is not filling
with water.
• At this point, the water tank is not full
and this message has to be reset. To reset
it, switch the power off and on.
• If the problem persists, check all
components on the water line (water filter,
tubing, fittings, etc.).
• Check inlet valve to make certain it is
functioning properly.
• In the case of a temporary disruption
with the water supply, the coffee maker will
reset itself after every hour.
Whipper Error
An error has been detected
with the whipper.
• The whipper motor may be jammed.
Clean the whipper assembly.
• Verify wiring to the whipper assembly.
• The whipper motor assembly may need