Service manual

Fibre Channel Router Card
1-8 Revision P 96041
Sun Confidential - Internal Only
Replacement
1. LLC card
2. SCSI Y cable J3 connector
1. Remove the card from its static-protected shipping bag.
2. If necessary, carefully pry out the electical knockout on the back panel for the fibre router card
using a screwdriver..
3. Insert the card into the library frame.
4. Connect the ribbon cables shown below.
CAUTION:
Equipment failure: Make sure that the SCSI connector to the LLC card is placed at
J18LS and the LLC jumper is set for LVD operation (see Figure 1-6 on page 1-25).
1. Fibre router connectors
2. LLC connector (J18LS)
5. Place the drawer interlock switch connector (J39) across the top of the Fibre Channel router card
and connect it to the LLC card.
6. Connect the power cable at J45.
L201_219
1
2