Service manual

96041 Revision P xxiii
Sun Confidential - Internal Only
Reinstall all equipment covers and close all equipment doors after you have
completed the work.
If the grounding-kit work surface has been exposed to temperatures above 66ºC
(150ºF) or below 4.5ºC (40ºF), acclimate the work surface to room temperature
before you unroll it.
Immediately place any component that you have removed into an ESD-protective
package.
Keep the grounding-kit work surface clean.
Note: To clean the work surface, use a mild detergent and water, and make sure
that the surface is completely dry before you use it.
Periodically check the electrical resistance of the ground cord and the wrist-strap coil
cord.
Note: The ground cord should measure less than 1.2 MΩ, and the coil cord
should measure between 0.8 and 1.2 MΩ. Repair or replace the cords if they
no longer meet these requirements.
ESD-Protection Procedure
Remember that each customer environment is different. Address all the customer’s
concerns before you work on any equipment.
Prepare the Work Area
1. Before you service the equipment, unfold the grounding-kit work surface
completely and place it on a convenient surface.
2. Attach one end of the ground cord to the work surface; secure the snap fastener.
Note: You will attach the free end in a later step.
3. Slip on an ESD wrist strap. Make sure that the strap is comfortable and makes
contact with the entire circumference of your wrist.
4. Snap one end of the coil cord to the wrist band.
Access the Equipment
5. Carefully open the doors to the equipment or remove the covers from the
equipment. Do not touch any internal components.
CAUTION:
Be sure that you are properly grounded before you touch any internal
components.
6. Attach the free end of the coil cord to the most appropriate place: