Service manual

PC to LLC Card Procedure
3-2 Revision P 96041
Sun Confidential - Internal Only
7. Unzip the file, leaving the unzipped files in this folder.
Note: Use a Zip program, such as WinZip, to unzip the file.
PC to LLC Card Procedure
1. Attach your PC to the Command Line Interface (CLI) port. This is the bottom port
on the LLC card.
2. From your PC:
For older PCs, click on Start>Programs>Accessories>Hyperterminal and open
a Hyperterminal session.
For WIN2000 PCs, click on Start>Programs>Accessories>Communications
>Hyperterminal and open a Hyperterminal session.
3. Configure the connection within the file properties:
4. Click on
OK.
5. In the Hyperterminal window, click on
ENTER.
The CSE> prompt appears.
6. Type download and press <
Enter>.
A message appears stating that you have two minutes to begin sending the new
firmware version.
7. Locate the
TRANSFER button at the top of the window, and point to SEND FILE.
A box appears, allowing you to browse to the file location of the files you unzipped in
“Web to PC Procedure” on page 3-1
8. Double-click on
release.prm.
The SEND FILE box appears, showing the pathname and the protocol chosen.
Protocol should be set to Z-MODEM.
9. Click on
SEND.
Table 3-1. Hyperterminal Connection:
Older PCs WIN2000 PCs
Baud rate = 38,400 Baud rate = 38,400
Data bits = 8 Data bits = 8
Parity bit = None Parity bit = None
Stop bit = 1 Stop bit = 1
Direct to comm flow = none Hardware flow control = on