Based on the above microSD card contents, once a Program Change
command with Program/Patch Number 64 is received, the system will
go inside folder “064” and consecutive Note ON commands will try to
trigger “.wav” files that are inside “064” folder. If a second Program
Change command with Program/Patch Number 0 is received, the
system will now go out of folder “064” and enter inside folder “000”,
then consecutive Note ON commands will try to trigger “.wav” files
that are inside “000” folder. In the case a folder does not exist or can’t
be opened, the system will return to the master folder or root path.
If the MIDI host that will control SmartWAV2 does not support Program
Change commands, then the “.wav” files must be placed on the
master folder or root path instead of “000” to “127” folders.