User`s guide

Table Of Contents
VIXEL INSPEED™ SAN STORAGE SWITCH MODEL 375 APPENDIX C EVENT MESSAGES
USERS GUIDE
EMBEDDED IN THE FUTURE OF STORAGE 66
APPENDIX C Event Messages
The event messages for the switch are listed below. For explanations, contact a customer service
representative. The message’s applicable severity level as defined below is also provided.
These severity levels can be used to designate which events trigger trap messages. Use the
Command Line Interface (CLI) to designate the minimum severity level of events to be logged in
the Event Log and at which severity level to illuminate the switch’s Fault LED.
Severity
Level
Severity Description
1 EMERG Immediate action required; system failing
2 ALERT Unrecoverable condition reported; major event in progress
3 CRIT Event failed with possible loss of integrity
4 ERR Condition failed; action required
5 WRN Failed event occurred; no action required
6 NOTIFY Configuration error or abnormal event occurred; no action required
7 INFO Event occurred; no action required
Event Event Message Severity
1 Message log cleared INFO
5 Power Supply # Failed ALERT
6 Power Supply # Online NOTIFY
7 Power Supply # Removed ALERT
8 Power Supply # Inserted NOTIFY
9 Fan has stopped EMERG
10 Fan has returned ALERT
19 Temperatures over limit ALERT
20 Temperature OK INFO
50 SPF Overvoltage EMERG
54 SOC has detected a CRC error in the EEPROM NOTIFY
70 PORT # bypassed NOTIFY
71 PORT # inserted NOTIFY
72 Transceiver detected at port # NOTIFY
73 Transceiver removed at port # NOTIFY
74 SEOC occurred on PORT # NOTIFY
75 Port exceeded OS threshold NOTIFY
76 Port exceeded CRC threshold NOTIFY
77 Loop UP on Port # NOTIFY
78 Loop DOWN on Port # NOTIFY
79 PORT received a LIP(F8) WRN