User`s guide

Table Of Contents
VIXEL INSPEED™ SAN STORAGE SWITCH MODEL 375 CHAPTER 3 SWITCH MANAGEMENT
USERS GUIDE
EMBEDDED
IN THE FUTURE OF STORAGE 31
When configuring multiple switches with a single cascade, use alternating ports. For
example, connect the second switch using ports 1 and the third using ports 2 as shown in
Figure 3-10.
To assign a Smart Setting to one or more ports:
1. Select the appropriate Smart Setting from the list box.
2. From the list of port numbers, select the ports that will use the selected Smart Setting
under the Assign heading.
3. Once completed, click Submit to save the settings.
To set all ports to the currently selected Smart Setting:
1. Select the desired Smart Setting from the list box.
2. Click Set All.
3. Click Submit to save the new settings.
Creating Custom Smart Settings
In addition to the default Smart Settings, users can create custom Smart Settings for use in a
specific network environment.
To create a custom Smart Setting:
1. Click Create.
A text box appears prompting for the name of the new Smart Setting.
2. Enter the new Smart Setting name.
A name may consist of up to 28 alphanumeric characters and cannot contain spaces (use
underscores for spaces in names).
3. Click OK.
The new Smart Setting is added to the list box.
4. Click Submit to save the new Smart Setting.
Note: The Create function always uses the Initiator or Target Smart Setting as the
base setting from which to configure a custom Smart Setting.
Figure 3-10: Alternating Ports for Single Cascades