Specifications

softek.fujitsu.com
Ports Tab
LICENSED MATERIAL - PROPERTY OF FUJITSU SOFTWARE TECHNOLOGY CORPORATION
75
Fabric
Address
Notification
When checked (enabled) and an initialization event
occurs, the Fabric port sends a Fabric Address
Notification (FAN) Extended Link Service to all FLOGI-
logged-in, attached ports. These ports can then
authenticate active Exchanges and operating parameters,
such as BB credits. FAN is available for public ports on a
Vixel 7100/7200 Switch running in Fabric or Fabric
(Public/Private) Mode (FAN is enabled by default in
these conditions).
PLOGI/
PRLI
When checked (enabled) and when one or more devices
on the selected switch port fail to register their FC-4
types within the expected time, the switch probes these
devices with a port login (PLOGI) and a process login
(PRLI) to obtain their FC-4 types, then registers the FC-4
types in the Simple Name Server (SNS) database.
PLOGI/PRLI is available for public ports on a Vixel
7100/7200 Switch running in Fabric or Fabric (Public/
Private) Mode (PLOGI/PRLI is enabled by default in
these conditions). Note: To find out how many devices on
this port responded to the PRLI probe for FC4 types, choose
Port Link Statistics from the View menu (of the Switch
window) and see the PRLIResp column.
EDTOV Error detection time-out value in milliseconds (period).
RATOV Resource allocation time-out value in milliseconds
(period).
ALTOV Loop initialization time-out value in milliseconds
(period); valid for FL_Port port type or one of the Stealth
Modes only.
Ports Tab Options
Textbox or
Selection Description