Specifications

softek.fujitsu.com
Sweep Tab
LICENSED MATERIAL - PROPERTY OF FUJITSU SOFTWARE TECHNOLOGY CORPORATION
123
Information in this dialog box is described in the tables below.
Sweep Tab Options 1
Field Possible values
Loop State Active (SOFs) - Data is going around the loop. Loop
is up.
Down - No Comma characters are going around the
loop.
Initializing - LIP(s) have been detected on the loop.
OpenInit - Initialization frames are being
transmitted and received in order to identify a loop
master and assign AL_PA values.
Up - A loop master has been identified and AL_PA
values have been assigned.
Sweep Tab Options 2
User Entry or
Selection Function
Default
Value
Update interval Determines the number of milliseconds
between sweep intervals.
4000
Port Detect for Determines the number of milliseconds
that Sweep monitors a specific port before
moving on to the next port.
300
(valid
range is
300 -
15,000)
(ordered set
pull-down
menu) under
Match
Lists ordered sets that can be selected for
matching.
ARB F(0)
K28.5 D fields
under Match
Allows you to define the pattern to be
matched by filling in valid Fibre Channel
data characters in the D fields. For
example, you could select the OPN
ordered set from the Match pull-down
menu, then add the specific source and
destination AL_PA values to the D fields
to find a more specific match than the
standard OPN( ) from the pull-down
menu.
--
Match Sig (1x) Constitutes a match with one occurrence of
the ordered set.
(selected)
Match Seq (3x) Constitutes a match with three consecutive
occurrences of the ordered set.
(not
selected)