Specifications
softek.fujitsu.com
Title Bar, LED Row, and Icons
LICENSED MATERIAL - PROPERTY OF FUJITSU SOFTWARE TECHNOLOGY CORPORATION
97
LEDs are described below.
HUB LEDs
Hub
LED
Green Yellow
Power OK N/A—not shown if powered off.
Loop OK (LoopUp
or LoopAc-
tive)
• Non Operational (no comma characters
are going around loop)
• Initializing (a Loop Initialization Primi-
tive (LIP) has been detected)
• OpenInit (initialization frames are being
transmitted and received to identify a
loop master and assign AL_PA values)
Note: For Vixel 2100 Managed Hubs with
more than one zone, the Loop LED repre-
sents the most urgent state existing among
the loops—to view each zone’s state,
choose Show Zones from the Options
menu.
Hub OK • Internal hub failure—an internal failure
was detected
• Self-test failure—the Power-On Self
Test (POST) failed and the system needs
attention
Environment OK • Fan fault
• Overtemp warning or fault
Port LEDs
Port LED On Off
Green
(top)
The inserted GBIC is healthy. (normal
operation)
Either no GBIC is
inserted or the GBIC is
unhealthy.
Yellow
(bottom)
The port is bypassed due to a prob-
lem detected by either the GBIC’s
transmit logic or the GBIC receiver.
Receiver problems include uncon-
nected fiber, remote node not
transmitting, LIP(F8), or a faulty
GBIC receiver.
The port is not
bypassed (normal oper-
ation).