Hardware manual
TITAN SILICONSERVER HARDWARE MANUAL 29
Management Interfaces
The Titan SiliconServer offers two types of physical management ports:
• Two RS232 Serial connections (DB-9)
• Four switched 10BaseT/100BaseTX Ethernet ports
All management ports are physically located on the NIM, and provide connections to ports within the
Titan Storage System cabinet only. The System Management Unit (SMU) in Titan provides the rack
component management function.
Serial Management Ports
The Titan SiliconServer has an RS232 connection that can be used as a management console
connection (Command Line Interface). The configuration functions can be performed from any VT100
terminal emulation interface.
Connect the terminal to port 1 on the rear of the server, then set the host settings to the values below
to ensure proper communication between the terminal and server.
Table 11: Host Setting Values
Terminal Requirement
Connection Crossover (nullmodem) cable
Protocol Asynchronous RS232
Baud rate 115,200 Bps
Data bits 8
Stop bits 1
Parity None
Flow control None
Two RS-232 Serial connections (DB-9)
Four
10/100BaseT