Installation guide

- 91 -
www.vivotek.com
Di <integer> 6/6 Indicate which di detected.
T
his field is required when trigger
condition is “di.
One bit represents one digital input.
The LSB indicates DI 0.
Mdwin <integer> 6/6 Indicate which motion detection
windows detected.
T
his field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
inter 1~999 6/6 Interval of period snapshot in minute.
T
his field is used when trigger
condition is “seq”.
weekday <interger> 6/6 Indicate which weekday is scheduled.
One bit represents one weekday.
The bit0 (LSB) indicates Saturday.
The bit1 indicates Friday.
The bit2 indicates Thursday.
The bit3 indicates Wednesday.
The bit4 indicates Tuesday.
The bit5 indicates Monday.
The bit6 indicates Sunday.
For example, to detect events on
Friday and Sunday, set weekday as 66.
begintime hh:mm 6/6 Begin time of weekly schedule.
endtime hh:mm 6/6 End time of weekly schedule.
(00:00 ~ 24:00 means always.)
action_do_i<0~(nd
o-1)>_enable
0, 1 6/6 To enable or disable trigger digital
output.