User's Manual
Table Of Contents
- Software Installation on page 10
- Overview
- Network Deployment
- Ready to Use
- Software Installation
- Accessing the Network Camera
- Using VIVOTEK Recording Software
- Using 3GPP-compatible Mobile Devices
- Using RTSP Players
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > DDNS
- Network > QoS (Quality of Service)
- Network > SNMP (Simple Network Management Protocol)
- Security > User Account
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- Security > IEEE 802.1x
- PTZ > PTZ settings 
- Event > Event settings
- Applications > Motion detection
- Applications > DI and DO
- Applications > Tampering detection
- Applications > Audio detection
- Applications > VADP (VIVOTEK Application Development Platform)
- Applications > Panoramic PTZ
- Recording > Recording settings
- Local storage > SD card management
- Local storage > Content management
- Appendix

VIVOTEK
User's Manual - 187
2: enable PTZ commands with UART
tunnel.
disablemdonptz <boolean> 0 1/4 Disable motion detection on PTZ
operation.
7.24 UART control
Group: uart (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] <product
dependent>
1/4 Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128] < product
dependent >
1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 0 4/4 Enable HTTP tunnel channel to
control UART.
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,120
0,2400,3600,480
0,7200,9600,192
00,38400,57600,
115200
9600 4/4 Set baud rate of COM port.
databit 5,6,7,8
6,7,8
<product
dependent>
8 4/4 Data bits in a character frame.
paritybit none,
odd,
even
none 4/4 For error checking.
stopbit 1,2 1 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
rs485 4/4 RS485 or RS232.
customdrvcmd_i<0~
9>
string[128] <blank> 1/4 PTZ command for custom camera.