User`s manual

VIVOTEK
User's Manual - 155
0: low
1: medium
2: high
daynight auto,schedule,da
y,night
auto 4/4 auto => auto daynight
night => ircut filter on
day => ircut filter off
schedule => scheduled ircut filter
7.10 IR cut control
Group: ircutcontrol (capability.nvideoinprofile > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
updateinterval 1~10 5 6/10 Update IR cut status interval
daymodebegintime 00:00~23:59 07:00 6/6 Day mode begin time
daymodeendtime 00:00~23:59 18:00 6/6 Day mod end time
sensitivity 0~28 8 6/6 Sensitivity of IR cut filter
7.10.1 Alternative IR cut control profiles
Group: ircutcontrol _profile
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
profilestatus <boolean> 0 6/6 Enable/disable this profile setting
Group: ircutcontrol _profile_i<0~(m-1)> (capability. nvideoinprofile > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
mode auto,
schedule,
day,
night
night 6/6 Active mode of this profile
daymodebegintime 00:00~23:59 07:00 6/6 Day mode begin time
daymodeendtime 00:00~23:59 18:00 6/6 Day mod end time
sensitivity 0~28 8 6/6 Sensitivity of IR cut filter