User`s manual

VIVOTEK
User's Manual - 117
IMPORTANT:
If the Alarm level and the received volume are set within a range of 20% on the wave
diagram, frequent alarms will be triggered. It is recommended to set the Alarm level
farther apart from the detected sound level.
To configure and enable this feature, you must not configure video stream #1 into
Motion JPEG. If an external microphone input is connected and recording of audio
stream is preferred, audio stream is transmitted between camera and viewer/recording
station along with stream #1.
Refer to page 61 for Audio settings, and page 55 for video streaming settings.