User Manual
Table Of Contents
- Overview
- Ready to Use
- Accessing the Network Camera
- Using VIVOTEK Recording Software
- Using 3GPP-compatible Mobile Devices
- Using RTSP Players
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Bonjour
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- PTZ > PTZ settings
- PTZ
- Mechanical PTZ Operation
- Event > Event settings
- Applications > Motion detection
- Applications > DI and DO
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Shock detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings
- Storage > Storage management
- Storage > Content management
- Appendix
VIVOTEK
392 - User's Manual
© 2019 VIVOTEK INC. All Right Reserved
258
PARAMETER VALUE DESCRIPTION
direction direct,
forward,
backward
Motor’s moving direction.
It works only if function=zoom or function=focus.
position 0~<motor_max> Motor’s position.
It works only if function=zoom or function= focus and
direction=direct.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
steps 1 ~ <motor_max> Motor’s moving steps.
It works only if function=zoom or function=focus and
direction=forward and direction=backward.
<motor_max> is refer to remote_focus_focus_motor_max or
remote_focus_zoom_motor_max which replied from
"function=getstatus"
* This parameter is for additional fine-
tune, the value is from 1 to
30.
iris N/A Open iris or not.
It works only if function=auto or function=scan.