di  <integer>  1  6/6  Indicate the source id of di trigger. 
This field is required when trigger 
condition is “di”. 
One bit represents one digital input. The
LSB indicates DI 0. 
mdwin  <integer>  0  6/6  Indicate the source window id of motion 
detection. 
This field is required when trigger 
condition is “md”. 
One bit represents one window. 
The LSB indicates the 1
st
 window. 
For example, to detect the 1
st
 and 3
rd
windows, set mdwin as 5. 
mdwin0  <integer>  0  6/6  Similar to mdwin. The parameter takes 
effect when profile 1 of motion detection
is enabled. 
vi  <integer>  0  6/6  Indicate the source id of vi trigger. 
This field is required when trigger 
condition is “vi”. 
One bit represents one digital input. The
LSB indicates VI 0. 
inter  1~999  1  6/6  Interval of snapshots in minutes. 
This field is used when trigger condition 
is “seq”. 
weekday  0~127  127  6/6  Indicate which weekday is scheduled. 
One bit represents one weekday. 
bit0 (LSB) = Saturday 
bit1 = Friday 
bit2 = Thursday 
bit3 = Wednesday 
bit4 = Tuesday 
bit5 = Monday 
bit6 = Sunday 
For example, to detect events on Friday 
and Sunday, set weekday as 66. 
begintime  hh:mm  00:00  6/6  Begin time of the weekly schedule. 
endtime  hh:mm 24:00  6/6  End time of the weekly schedule. 
(00:00 ~ 24:00 sets schedule as always
on)