User`s manual
Table Of Contents
- Overview
- Accessing the Network Camera
- Using 3GPP-compatible Mobile Devices
- Using RTSP Players
- Using VIVOTEK Recording Software
- Main Page
- Client Settings
- Configuration
- System > General settings
- System > Homepage layout
- System > Logs
- System > Parameters
- System > Maintenance
- Media > Image
- Media > Video
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > SNMP (Simple Network Management Protocol)
- Security > User Account
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List
- PTZ > PTZ settings
- Event > Event settings
- Applications > Motion detection
- Applications > DI and DO
- Applications > Tampering detection
- Applications > Audio detection
- Applications > VADP (VIVOTEK Application Development Platform)
- PIR
- Recording > Recording settings
- Local storage > SD card management
- Local storage > Content management
- Appendix
VIVOTEK
198 - User's Manual
7.31 Event setting
Group: event_i<0~2>
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
name string[40] <blank> 6/6 Identification of this entry.
enable 0, 1 0 6/6 Enable or disable this event.
priority 0, 1, 2 1 6/6 Indicate the priority of this event:
“0” = low priority
“1” = normal priority
“2” = high priority
delay 1~999 20 6/6 Delay in seconds before detecting the
next event.
trigger boot,
di,
p i r,
motion,
seq,
recnotify,
tampering,
visignal,
vi,
volalarm,
vadp
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“pir”= PIR
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
“volalarm”= Audio detection
“vadp” = VADP trigger
triggerstatus String[40] trigger 6/6 The status for event trigger
exttriggerstatus trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event DI 1 trigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.