User`s manual
VIVOTEK
User's Manual - 165  
position. 
i<0~(m-1)>_win_i<0~2>_top  0 ~ 240  0  4/4  Top coordinate 
of window 
position. 
i<0~(m-1)>_win_i<0~2>_width  0 ~ 320  0  4/4  Width of motion 
detection 
window. 
i<0~(m-1)>_win_i<0~2>_height 0 ~ 240  0  4/4  Height of motion 
detection 
window. 
i<0~(m-1)>_win_i<0~2>_objsize  0 ~ 100  0  4/4  Percent of 
motion
detection 
window. 
i<0~(m-1)>_win_i<0~2>_sensitivity  0 ~ 100  0  4/4  Sensitivity of 
motion
detection 
window. 
7.16 Tempering detection settings 
Group: tampering_c<0~(n-1)> for n channel product (capability.tampering > 0)
NAME VALUE  DEFAULT  SECURITY 
(get/set) 
DESCRIPTION 
enable  <boolean>  0  4/4  Enable or disable tamper detection. 
threshold  0 ~ 255  32  1/7  Threshold of tamper detection. 
duration  10 ~ 600  10  4/4  If tampering value exceeds the ‘threshold’ for 
more than ‘duration’ second(s), then tamper 
detection is triggered. 