User`s manual
VIVOTEK
142 - User's Manual
<product dependent>  0 => Inactive 
1 => Active 
(capability.nvi > 0) 
7.3 digital input behavior define 
Group: di_i<0~(ndi-1)> (capability.ndi > 0) 
NAME VALUE  DEFAULT  SECURITY 
(get/set) 
DESCRIPTION 
normalstate high, 
low 
high  1/1  Indicates open circuit or 
closed circuit (inactive 
status) 
7.4 digital output behavior define 
Group: do_i<0~(ndo-1)> (capability.ndo > 0)
NAME VALUE  DEFAULT  SECURITY 
(get/set) 
DESCRIPTION 
normalstate open, 
grounded
open  1/1  Indicate open circuit or 
closed circuit (inactive 
status) 
7.5 security 
Group: security 
NAME VALUE  DEFAULT  SECURITY 
(get/set) 
DESCRIPTION 
privilege_do 
<product dependent> 
view, operator, 
admin 
operator  1/6  Indicate which privileges 
and above can control 
digital output 
(capability.ndo > 0) 
privilege_camctrl 
<product dependent> 
view, operator, 
admin 
view  1/6  Indicate which privileges 
and above can control PTZ
(capability.ptzenabled > 0 
or capability.eptz > 0) 
user_i0_name  string[64]  root  6/7  User name of root 
user_i<1~20>_name  string[64]  <blank>  6/7  User name 
user_i0_pass  password[64]  <blank>  6/6  Root password 
user_i<1~20>_pass  password[64]  <blank>  7/6  User password 
user_i0_privilege  view,  admin  6/7  Root privilege 