7.2 status 
Group: status
NAME VALUE  DEFAULT  SECURITY 
(get/set) 
DESCRIPTION 
di_i<0~(ndi-1)>  <boolean>  0  1/7  0 => Inactive, normal 
1 => Active, triggered 
(capability.ndi > 0) 
do_i<0~(ndo-1)> <boolean>  0  1/7  0 => Inactive, normal 
1 => Active, triggered 
(capability.ndo > 0) 
daynight  day, night  <product 
dependent> 
7/7  Current status of day, 
night. 
onlinenum_rtsp  integer  0  6/7  Current number of RTSP 
connections. 
onlinenum_httppush  integer  0  6/7  Current number of HTTP 
push server 
connections. 
eth_i0  <string> <product 
dependent> 
1/7  Get network information 
from mii-tool. 
vi_i<0~(nvi-1)>  <boolean>  0  1/7  Virtual input 
0 => Inactive 
1 => Active 
(capability.nvi > 0) 
7.3 digital input behavior define 
Group: di_i<0~(ndi-1)> (capability.ndi > 0) 
NAME VALUE  DEFAULT  SECURITY 
(get/set) 
DESCRIPTION 
normalstate high, 
low 
high  1/1  Indicates open circuit or 
closed circuit (inactive 
status) 