Manual
VIVOTEK
User's Manual - 157  
URL Command Document for All Series2V
    35    
position. 
win_i<0~2>_top  0 ~ 240  0  4/4  Top coordinate of window 
position. 
win_i<0~2>_width  0 ~ 320  0  4/4  Width of motion detection 
window. 
win_i<0~2>_height  0 ~ 240  0  4/4  Height of motion detection 
window. 
win_i<0~2>_objsize  0 ~ 100  0  4/4  Percent of motion detection 
window. 
win_i<0~2>_sensitivity  0 ~ 100  0  4/4  Sensitivity of motion detection 
window. 
Group: motion_c<0~(n-1)> profile for m profile and n channel product (capability.nmotionprofile > 
0)
NAME  VALUE  DEFAULT SECURITY 
(get/set) 
DESCRIPTION
i<0~(m-1)>_enable  <boolean>  0  4/4  Enable profile 1 ~ 
(m-1). 
i<0~(m-1)>_policy day, 
night, 
schedule
night  4/4  The mode which the 
profile is applied to. 
i<0~(m-1)>_begintime  hh:mm  18:00  4/4  Begin time of 
schedule mode. 
i<0~(m-1)>_endtime  hh:mm  06:00  4/4  End time of 
schedule mode. 
i<0~(m-1)>_win_i<0~2>_enable  <boolean>  0  4/4  Enable motion 
window. 
i<0~(m-1)>_win_i<0~2>_name string[14]  <blank>  4/4  Name of motion 
window. 
i<0~(m-1)>_win_i<0~2>_left  0 ~ 320  0  4/4  Left coordinate of 
window position. 
i<0~(m-1)>_win_i<0~2>_top  0 ~ 240  0  4/4  Top coordinate of 
window position. 
i<0~(m-1)>_win_i<0~2>_width  0 ~ 320  0  4/4  Width of motion 
detection window. 
i<0~(m-1)>_win_i<0~2>_height 0 ~ 240  0  4/4  Height of motion 
detection window. 
i<0~(m-1)>_win_i<0~2>_objsize 0 ~ 100 0 4/4 Percent of motion 
detection window.