NAME VALUE SECURITY
(get/set)
DESCRIPTION
ensitivity_type=normalize
* Only available when
"capability_daynight_c<0~(n-1)>
_ircutsensitivity_type" is not "-".
* We replace this parameter with
ircutcontrol_c<0~(n-1)>_sensitivity
when the version number
(httpversion) is equal or greater than
0312a.
* We do not support this parameter
when "capability_nvideoin > 1".
* This parameter will not be used
after the version number (httpversion)
is equal or greater than 0400a.
spectrum_mode
<Not
recommended to
use this>
visible,
ir,
irenhanced,
blueenhanced
<product dependent>
* Available values are
listed in
"capability_daynight_
c<0~(n-1)>_spectrum
_mode".
6/6 Set spectrum method .
* Only available when
"capability_daynight_c<0~(n-1)>_spec
trum_support" is 1.
* We replace this parameter with
"ircutcontrol_illuminators_spectrum_
mode" when the version number
(httpversion) is equal or greater than
0312a.
* We do not support this parameter
when "capability_nvideoin > 1".
* This parameter will not be used
after the version number (httpversion)
is equal or greater than 0400a.
7.10.1 IR cut control setting per channel
Group: ircutcontrol_c<0~(n-1)> for n channel products (capability_daynight_c<0~(n-1)>_support >
0)
n denotes the value of "capability_nvideoin"
NAME VALUE SECURIT
Y
DESCRIPTION
© 2020 VIVOTEK INC. All Right Reserved
95
(get/set)
mode auto,
day,
night,
di,
schedule…etc
* Available values
are listed in
"capability_daynig
ht_c<0~(n-1)>_mo
de"
<product
dependent>
6/6 Set IR cut control mode
* We support this parameter when
the version number (httpversion) is
equal or greater than 0312a.
sir
<product dependent>
<boolean> 6/6 Enable/disable Smart IR
* Only available when
"capability_daynight_c<0~"capability_
nvideoin"-1>_smartir" is 1
* We support this parameter when
the version number (httpversion) is
equal or greater than 0312a.
daymodebegintime 00:00~23:59 6/6 Day mode begin time
* We support this parameter when
the version number (httpversion) is
equal or greater than 0312a.
daymodeendtime 00:00~23:59 6/6 Day mod end time
* We support this parameter when
the version number (httpversion) is
equal or greater than 0312a.
bwmode <boolean> 6/6 Switch to B/W in night mode if
enabled.
* Only available when
"capability_daynight_c<0~(n-1)>_
blackwhitemode" is 1.
* We support this parameter when
the version number (httpversion) is
equal or greater than 0312a.
sensitivity low,normal,high,1
~100
6/6 Sensitivity of day/night control.