User Manual
Table Of Contents
- Software Installation on page 10
- Revision History
- Overview
- Network Deployment
- Accessing the Network Camera
- Main Page
- Client Settings
- Configuration
- System > Homepage layout 
- System > Logs 
- System > Parameters 
- System > Maintenance
- Media > Image 
- Media > Video
- Media > Audio
- Network > General settings
- Network > Streaming protocols
- Network > QoS (Quality of Service)
- Network > SNMP (Simple Network Management Protocol)
- Network > FTP
- Security > User accounts
- Security > HTTPS (Hypertext Transfer Protocol over SSL)
- Security > Access List 
- Security > IEEE 802.1x
- PTZ > PTZ settings
- Event > Event settings 
- Applications > Motion detection
- Applications > Tampering detection
- Applications > Audio detection
- Applications > Package management - a.k.a., VADP (VIVOTEK Application Development Platform)
- Recording > Recording settings 
- Appendix
VIVOTEK
182 - User's Manual
57
600,115200
databit 5,6,7,8
6,7,8
<product
dependent>
8 4/4 Data bits in a character
frame.
paritybit none,
odd,
even
none 4/4 For error checking.
stopbit 1,2 1 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
rs485 4/4 RS485 or RS232.
customdrvcmd_i<0
~9>
string[128] <blank> 1/4 PTZ command for custom
camera.
speedlink_i<0~4>_
name
string[40] <blank> 1/4 Additional PTZ command
name.
speedlink_i<0~4>_
cmd
string[128] <blank> 1/4 Additional PTZ command
list.
ptzdriver 0~19,
127 (custom),
128 (no driver)
128
(no driver)
4/4 The PTZ driver is used by
this COM port.