Micro Chip Display Projection TV User Guide Model name VESA
 Status LEDs 
There are two status LEDs on the front of your Micro Chip Display Projection TV. 
 Normal Operation 
State  Power LED Lamp LED Description 
AC off  Not lit Not lit   AC power not connected 
Standby mode  Orange Not lit AC power is connected and 
your RPTV is in standby 
mode.
Warm-up  Blue Orange Flashing AC power is connected and
  the power button has just been 
   turned on. 
Cool down  Orange Orange Flashing Powering off.
Operation mode  Blue Not lit AC power is connected, the 
power button has been 
pressed, and the lamp has 
warmed up.
 Error Codes 
Error 
Code 
Power LED  Lamp LED Description 
21 
Flashes blue twice, 
then orange once. 
Not lit 
One of the cooling fans has failed. 
See “Support” on page 49. 
32 
Flashes blue three 
times, then orange 
twice. 
Flashing 
Lamp trouble or failure. Your RPTV 
automatically shut down and 
restart itself. If this does not solve 
the problem, see “Support” on 
page 49. 
52 
Flashes blue five 
times, then orange 
twice. 
Not lit 
Hardware error. Shut off your 
RPTV, wait one minute, then 
restart your RPTV. If this does not 
solve the problem, see “Support” 
on page 49. 