2.9.2 The Classic Screen
The Classic Screen has all the functions normally seen on a classic cable locator. The main functions being:
69.9
32.8kHz58dB 2’7”
50mA
4G
3
21
4
5
6
7
8
1 Percentage of signal strength (mirrors (4) the bar graph) 5
Signal Direction forward/back arrows (only active with
Signal Direction frequencies)
2 Peak level indicator 6
360° Compass line direction indicator (turns blue when
aligned with the target line)
3 Gain setting 7
Left/Right direction to target line indicators (when in
applicable locate mode)
4
The signal strength bar graph will change color with the
level of signal distortion:
Green: Low distortion electromagnetic eld
Blue: Minor distortion in the electromagnetic eld
Red: Excessive distortion electromagnetic eld
8
Frequency selection (ashing frequency indicates
frequency selection is not valid for this screen. Choose
another frequency)
Radio
SD-EUR
8kHz
8KFF
33kHz
83kHz
200kHz
TIP
When in a locate screen, pressing and holding the “f”
key will bring up the frequency table.
Use the “+” and “-” keys to navigate quickly to the
desired frequency. Press the “i” key to select a
highlighted choice and return to the locate screen.
2.10 Classic Locating Modes (Response)
The vLoc3 RTK-Pro receiver has an array of six antennas, and these can be toggled through dierent congurations (modes) to
provide dierent responses to the signals radiating from buried utilities. The modes are:
2.10.1 Peak Response Mode
Two horizontal antennas provide a “Peak” or maximum signal response over the buried line.
This is an accurate locating method as both horizontal antennas are used to provide a clearly
identiable “Peak.” It is also less prone to the eects of signal distortion.
The Peak Level Indicator on the bar graph indicates the point of the largest signal detected,
allowing the user to return to this point quickly.
The compass (line direction indicator) aligns itself parallel to the cable (available in Active modes).