User's Handbook

Page 8 of 66
2 vLoc3 RTK-Pro Receiver
Transmitter Control
– This feature is used to control a transmitter with the Radio Link activated remotely. For more
information, see the section “Remote Operation of the transmitter.”
DFT
Discrete Fourier Transform is a tool to help choose a frequency to apply to the target conductor. The DFT feature will aid
the user with nearby interference that may a󰀨ect the locate quality.
Cloud
– This menu item ties the VMMap Cloud-based app to the RTK-Pro unit. Use this menu item to check the Cloud connection
status. To use the Vivax-Metrotech Cloud-based VMMap app setup an account and register each locator that will use the app.
GPS RTK Source
– Enter this option to check RTK connectivity and to select the RTK source.
For more information check the section on Setting up RTK Connectivity.
New Survey
– Navigating into this menu and selecting a survey type always causes a new survey to be initiated in the SD
Card Data Logger. This will happen even if it is the same type as the previous log record.
Di󰀨erent Survey types can be selected, as shown.
Electric
Gas
Communications
Potable Water
Reclaimed Water
Sewer
Temporary Survey
Proposed Excavation
Oil
2.4.4 Setup – Informational
About
– This section holds the data about the locator, such as software revision, calibration data, etc.
Regulatory Labels
– This section shows the required FCC ID and IC information. To access this information do the following:
1. Press and hold the Information pushbutton.
2. Use the – and + pushbuttons to highlight “Regulatory Labels.”
3. Press the Enter button when About is highlighted.
Self-Test
– The vLoc3 series receivers have a self-test feature that conrms the equipment is t for use and that the calibration
has not drifted from its expected settings.
Satellite Information
– Enter this menu item to show all current satellite information.
2.5 Self-Test
The self-test feature must be run in an area free from interference, such as overhead uorescent lighting, large transformers,
etc. Also, check that any nearby transmitters or sondes are switched o󰀨.
Select “Self-Test” from the user menu and press the “Return” button. Keep the receiver stationary while the test is running. After
a short while, the test will complete, and the unit will report Passed or Failed.
Self Test: PASSED
110.3
110.3
64.1
110.3
110.3
64.1
Self Test: FAILED
109.6
109.9
64.3
109.7
109.9
64.5
Examples of the self-test results
If the receiver fails the test, try again in an area with less interference. If it continues to fail, return the unit to Vivax-Metrotech or
one of its approved repair centers for investigation.