Specifications
23
OSD OPERATION
MOTION
AREA
SENSITIVITY
DISPLAY
HOLD TIME
ALARM OUTPUT
RETURN
MOTION
OFF
025
TRACE
003
OFF
SENSITIVITY : Control MOTION sensitivity. (1 ~ 30, 1 step)
DISPLAY: Control alarm mode when MOTION indicates. ( Select of OFF / MESSAGE / TRACE)
i) MESSAGE mode: MOTION ICON display when MOTION indicates.
ii) TRACE mode: Display selected window in AREA
HOLD TIME: The time of alarm control when MOTION indicat. ( 1 ~ 15, 1 step ) Unit : sec
ALARM OUTPUT : Select operates ON/OFF
RETURN : Select this to save the changes in the menu and return to the MAIN menu.
The mask controls about the zone where the privacy is necessary. The total mask is 8 zones.
The each mask color can control GRAY, BLACK, WHITE, RED, GREEN, BLUE, MAGENTA, CYAN.
EXPOSURE
WHITE BALANCE
DAY&NIGHT
IMAGE ADJUST
MOTION
PRIVACY
SPECIAL
EXIT
MAIN MENU
PRIVACY
** NOTE: The ‘ALARM OUTPUT’ feature mentioned above is available by Special Order only.