Instruction manual
VITEK VT-DVR Series
61
3. ALARM BUZZER
The DVR emits a high pitched, continuous buzzer
when the alarm is triggered and starts to record.
The buzzer will sound for the duration of the
Record Duration. Press the cancel button to
stop the buzzer immediately. Stopping the
buzzer does not stop the alarm recording. The
buzzer is also heard when the HDD fails, and will
continue to buzz until the HDD failure has been
addressed. The default setting is off.
4. ALARM OUT
The DVR sends an electric signal when alarm is
triggered to activate external devices such as
speakers or other types of relays that accept
electric triggers. Two levels of output are
available:
Low: 0.1 volt ~ 0.8 volt
High: 4.0 volt ~ 5.0 volt
The maximum output is 1 mAmp, 5 VDC
5. CAMERA SELECT
This option configures the motion grid to trigger
the motion recording. It adjusts the motion
sensitivity level and alarm input type. Use the left
and right directional buttons to select each
camera or the numeric buttons to jump directly to
the desired camera.