- Open configuration file of the board (ActiveProfile.xml) in a text editor
- Search for the strings:
<Property AccessFlags="512" Current="0" Default="0" Name="Show Info Window"/>
<Property AccessFlags="512" Current="94371840" Default="0" Max="125830200"
Min="0" Name="Info Window Coordinates"/>
- Set values:
<Property AccessFlags="512" Current="1" Default="0" Name="Show Info Window"/>
<Property AccessFlags="512" Current="0" Default="0" Max="125830200" Min="0"
Name="Info Window Coordinates"/>
- Save the configuration file.
- Reopen the configuration in PlayerLW(m). When the configuration starts an information
window appears in the left upper corner of display.
- Find genlock group in the information window.
- If the board is genlocked the State is LOCKED.
NOTE:
If the board is run in 60fps, Secondary SD-SDI output works not synchronously with Primary HD-
SDI output and mustn’t be used as SDI-synchronisation output or configured as a source for genlock.