DIAGNOSTIC & TROUBLESHOOTING
Resetting Your Spa
Like your PC at home, your spa electronics could get corrupted by electrical surges and operate
improperly. If your spa system is not operating properly or shows any of the following messages,
please reset it before calling for service to see if the malfunction disappears.
Turn power off for 5 full minutes –then– Turn power back on –then– Press "PROG" to show time
–then– Hold "UP" for 5 seconds. Display will show 12:00 PM, indicating a successful reset (reboot).
SYMP TO M
Spa Inoperative
MESSAG E
FLO
HILI
ICE
LS=0 or LS=S
SS=0 or SS=S
PB
ME A NIN G
Power failure outside of spa.
Lack of water flow through
Heater.
a . Overheating detected in spa
w a t e r. Spa pumps and heater will
turn off at 112F for overheat
protection. HILI message is not
displayed. D O N OT ENTER THE
WAT E R .
b . HILI message appears if the
high-limit sensor detects 118F at
the spa heater. DO NOT ENTER
T H E WAT E R .
Water in plumbing below 50 F
Call for service if spa fails to
come on.
Water temperature sensor
High Limit sensor
Break in communication.
AC T I O N
Check power source Breaker and GFCI;
Reset breaker/GFCI. Call Electrician if it
will not start.
Remove filter and check for debris in
filter and filter adapter. If ”FLO” remains
check for closed gate valves or see
priming the pump.
See page 15 (Overheat Protection).
Remove the spa cover and let the
water temperature cool down to 10 4 F.
Reset as shown above "Resetting Yo u r
Spa". If your spa reaches 112F again,
contact your dealer for service.
Turn off all power to the spa and
contact your dealer for service.
No action required. Pump will come
on to circulate water and then heater.
Heater will stay on until water reaches
60 F or set temperature.
Reset spa. If message comes back, call
for service.
Reset spa. If message comes back, call
for service.
Reset spa. If message comes back, call
for service.