5.6.2 Event Icon >
The item enables (ON) / disables (OFF) the display of Event Icon on the main
monitor when an alarm event occurs. The default setting is <ON> (enable).
The event types are represented by a character respectively; the descriptions
are as below table.
Event type Description
A Alarm in event
M Motion detection event
L Video loss event
5.6.3 Event Duration >
This item determines the duration of the buzzer and Alarm Out relay function
after an alarm is triggered. The available event duration range is from 1
second to 100 seconds. The default setting is 5 seconds.
5.6.4 Per Channel Config >
This menu is used to set the Video Loss Detect, Motion Detect and Alarm In /
Out function for each channel. The menu is displayed as below.
Per Channel Config
1. Channel Select
2. Video Loss Detect
3. Motion Detect
4. Detection Config
5. Alarm In
6. Alarm Out
CH1
ON
ON
OFF
None
5.6.4.1 Channel Select >
The item is used to select a desired channel for setting the parameters. Move
the cursor to <Channel Select> and press ENTER, then select a channel
using UP / DOWN keys. Press ENTER again to confirm the setting.