Specifications

Inspection Kits
Site inspection requires a range of portable testing equipment. In order to
make these products easily available and transportable, Elcometer have
developed a range of Coating Inspection Kits. All gauges are conveniently
stored in a hard plastic protective carrying case and are supplied with full
operating instructions.
COATING THICKNESS GAUGES
Product Code Description
NCG0002 Elcometer Model 456
For precise measurement of coatings, the new Elcometer 456 heralds radical new advances in
both design and performance. Ergonomic styling for the ultimate in hand-held comfort. Full,
menu driven, graphics display for ease of use. Greater than 60 readings per minute for fast
results. Enhanced memory capability for data storage. Unrivalled accuracy and repeatability for
the ultimate hand-held performance. Integral and plug-in probe options for total versatility plus a
choice of three models and a host of other carefully developed benefits that really do place the
future of coating thickness measurement in the palm of your hand.
456 RANGE
FEATURES
456
BASIC
456
STANDARD
456
TOP
Multiple Calibration Adjustment Options (Including factory
calibration reset)
· · ·
Backlight
· · ·
Metric / Imperial units
· · ·
Bleeper
· · ·
LED Indicator
· · ·
Statistics (No. of readings, Mean, Highest / Lowest readings,
Standard Deviation, Co-efficient Variation)
· · ·
Infrared Data Output (HP IR Printer)
· · ·
Cable Data Output (Printer, Computer & Data Logger)
· ·
Readings Memory
250
in one batch
40,000
in up to
999 batches
Average and Counted Average
· ·
Individual Reading Review
· ·
PC Software
EDTS
EDCS
EDTS
Limits
· ·
Clock and Alarm
·
PROBE SPECIFICATIONS
Ferrous (F) operation using electromagnetic induction probes for all non-magnetic coatings on a ferrous
(magnetic) substrate, e.g. Steel, cast iron, ferritic and duplex stainless steel substrates.
Non-Ferrous (N) operation using eddy current probes for non-conductive coatings on non-ferrous metal
substrates, e.g. Aluminium, brass, zinc, stainless steel, copper, titanium substrates.
Dual (FNF) operation combines the Ferrous and Non-Ferrous operation in a single probe. The gauge has user
selection for auto or manual substrate determination.
Back to Contents
Page 39 of 48