Installation Sheet
1. Carefully remove all parts from the box.
2. Remove the mounting plate (B) from the fixture body (E) by loosening the branch (H),
hex nut (G) and branch (F) by using the wrench (I).
3. Install the mounting plate (B) to the junction box and secure with the mounting screws (C).
4. Connect the safety cables as shown in figure.
5. Wrap the fixture ground wire to the green ground screw on the mounting plate (B) and
secure,then connect to the ground wire in the junction box using the wire nut (A).
IT IS IMPERATIVE THAT THIS FIXTURE BE GROUNDED.
6. Connect the fixture white wire to the neutral wire in the junction box using the wire nut (A).
7. Connect the fixture black wire to the hot wire in the junction box using the wire nut (A).
DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS OTHERWISE SAFETY
WILL BE COMPROMISED.
8. Attach the fixture with branch (F) to the threaded nipple (D) and secure with the hex nut (G)
using the wrench (I) provided.
9. Thread the branch (H) to the bottom of threaded nipple (D).
10. Insert bulbs (not included) into the sockets.
11. Installation is complete, turn on power at fuse or circuit breaker.
***Clean with a dry, soft cloth only. Use no harsh abrasives or chemical agents.
Strada Small Flush Mount
Item # KW 4065
WE RECOMMEND INSTALLATION OF THIS LIGHTING FIXTURE BE DONE BY A
LICENSED ELECTRICIAN.
WARNING***SWITCH OFF THE MAIN ELECTRICAL SUPPLY FROM THE MAIN
FUSE BOX/CIRCUIT BREAKER BEFORE INSTALLATION.
INSPECT ITEM CAREFULLY BEFORE ATTEMPTING TO INSTALL. IF THERE IS ANY
DAMAGE OR OBVIOUS DEFECT. DO NOT INSTALL.
ITEM MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED.
NOTE: CAREFULLY UNPACK EACH PIECE IN TOP LAYER OF PACKING PRIOR TO
REMOVING. RETAIN ALL PACKING MATERIAL UNTIL INSPECTION AND
INSTALLATION ARE FINAL.
ASSEMBLY INSTRUCTIONS
Bulb
(Not included)
Junction box
US
M
L
I
D
S
E
T
A
B
C
D
E
DAMP
Cable lock nut
Safety cable
TO assemble safety cables:
1.Join fixture safety cables with safety
cable from ceiling.
2.Wrap both safety cable around the
cable lock nut.
3.Insert screws into both holes on cable
lock nut,secure screws with screwdriver.
4.Push the cable lock nut into junction box.
F
G
H
I