Installation Sheet
.
DAMP
1. Carefully remove all parts from the carton.
WE RECOMMEND INSTALLATION OF THIS LIGHTING FIXTURE BE DONE BY A
LICENSED
ELECTRICIAN.
WARNING *** SWITCH OFF THE MAIN ELECTRICAL SUPPLY FROM THE MAIN
FUSE BOX/CIRCUIT BREAKER BEFORE INSTALLATION.
INSPECT ITEM CAREFULLY BEFORE ATTEMPTING TO INSTALL. IF THERE IS
ANY DAMAGE OR OBVIOUS DEFECT, DO NOT INSTALL.
ITEM MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED.
2. Remove mounting plate (B) from fixture base (H) by removing base screws (G).
3. Remove cap (E) from mounting plate (B) by removing cap nuts (F).
4. Position mounting plate (B) on the ceiling outlet box. Mark center points for three mounting
holes with a pencil on the ceiling. Remove mounting plate (B).
5. Drill small holes on each point location on the ceiling, each hole should be large enough to
accommodate to the plastic anchor (A). Push plastic anchors (A) into the holes in the ceiling.
6. Affix mounting plate (B) to ceiling oultet box, aligning holes and secure by inserting mounting
screws (D) to the holes of outlet box and screws (C) to the plastic anchors (A) in the ceiling.
7. Gently pull the wires from the ceiling outlet through the center hole in moutning plate (B).
8. Attach ground (green) wire to ground wire from wall outlet box (usually green or copper
in color ), fasten together with a plastic wire connector. Tightly wrap the wire with electrical
tape. so the end of the connector is sealed. IT IS IMPERATIVE THAT THE OUTLET BOX
IN YOUR HOME BE PROPERLY GROUNDED.
9. Connect neutral (white ) fixture wire coming from fixture base to neutral (usually white )
outlet wire. Fasten both wires together with a plastic wire connector and tightly wrap the
wire connector with electrical tape.
10. Repeat the procedure with the hot (black) wire. Always make sure that no wire strands are
left outside the connectors. DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS
OTHERWISE SAFETY WILL BE COMPROMISED.
11. Replace cap (E) to mounting plate (B) and secure with cap nuts (F).
12. Attach fixture base (H) to mounting plate (B) and secure with base screws (G).
13. Restore power and test fixture. Installation is complete.
*** Clean with a dry, soft cloth only. Use no harsh abrasives or chemical agents.
Halo Large Flush Mount
Item # BBL 4096
ASSEMBLY INSTRUCTIONS
A
B
D
C
E
F
G
H