Service manual

2. General Description
CHRISTIE INC. - 35/70 Service/PM Manual
July, 1997
ENTRY:
<CMD-C>, <6>
CODE:
C6
ACTION
S:
Projector logs all BOF and EOF sensor tapes on the reel.
STATUS:
Unchanged.
Table 2.5 illustrates the sequence of commands necessary for auto-logging. In this example, the number of
shows is equal to five, and the first show to be shown after all cues have been logged is Show #2.
Command Input Result Reference
(Load the film on the reel so
that the BOF tape for Show #1
is above the gate or on the
supply reel.)
Chapter 3
READY
<READY> Puts projector into
READY mode.
Section 0
SET MAX SHOWS = 5
<H> , <D> ,
<5>
Sets number of shows
to 5.
Section 0
SET NEXT SHOW = 1
<H> , <8> ,
<1>
Sets Show #1 as next
show.
Section 0
SET CURRENT SHOW = 1
<H> , <5> ,
<1>
Sets current show to 1. Section 0
CUE
<CUE> Projector cues on BOF
of Show #1.
Section 0
AUTO LOG
<C> , <6> Projector logs all BOF
and EOF tapes on the
reel.
Section 0
SET NEXT SHOW
<H> , <8> ,
<2>
Sets Show #2 as next
show.
Section 0
CUE
<CUE> Projector cues on BOF
of Show #2.
Section 0
Table 2.5: Command Sequence for Auto Logging