User manual
Program UM0036
330/385 Doc ID 7705 Rev 11
1. Right-click in the option byte’s Description field to see the pop-up list of possible
settings.
2. Click on the new setting in the pop-up list.
The new setting for the option byte is displayed in the Description field.
“Program even if default” option
The Programmer only programs the Option Byte Area of memory if the settings indicated in
the Option Bytes tab are different from the factory default settings. However, you can check
the Program even if default option and the Programmer will program the default option
byte settings shown in the OPTION BYTE tab.
This option is useful when you are programming to a microcontroller that has already been
programmed. By using this option, you can ensure that the option bytes are set to the
factory defaults.
11.4 Starting the programming sequence
With the Programmer window open (Tools>Programmer), select the Program tab. In this
tab, you can confirm the programming settings, start the programming sequence and
monitor the programmers progress (Figure 261).
Figure 261. Programmer program view
Before your begin the programming sequence, the Summary and Outputs field contains
information about the settings you have applied. This information includes:
● Device (the target MCU)
● Board (your programming hardware)
● Port
● Programming Mode
● Tasks (the sequence of tasks that the programmer will execute)