Owner`s manual
9
Operating Instructions
The Feed Rate Trim and Combustion Blower Trim are used to fine tune the operation of the unit for
varying fuels� Both trim settings will affect the operation in all modes, and across all heat levels�
The trim settings can be adjusted in any mode (Manual, High/Low, Auto/Off), but only when the unit is
in operation�
Trim settings cannot be adjusted while the unit is in a startup or shutdown cycle.
aDjuSting tRim SettingS
Determining the Current Trim Setting:
When one of the trim buttons are pressed the control panel will
display the current setting for that trim feature� Four of the
lights on the heat level display will come on, the light that is off
shows the current setting�
Changing a Trim Setting:
To change a trim setting, hold down the button for the setting
you would like to change� The current setting for that trim will
be displayed� While holding the trim button, press either the
heat level up or heat level down button to adjust the trim in
that direction�
Feed Rate Trim:
The feed rate trim allows the user to fine tune the fuel feed
setting� Trim up to increase the feed setting, trim down to
decrease the feed setting� The factory setting for the feed rate
trim is #4�
Combustion Blower Trim:
The combustion blower trim allows the user to fine tune the
combustion air flow setting� Trim up to increase the amount of
air fed to the fire, trim down to decrease the air� The factory
setting for the combustion blower trim is #2�
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
Figure 7: Trim set to #4 setting.
Room aiR fan on/off
The Room Air Fan On/Off control allows the user to reduce the noise level
of the unit temporarily by turning the Room Air (heat distribution) fan off�
If the unit begins to overheat; the Room Air Fan control will be bypassed
automatically and the fan will come on HIGH to cool the unit down� Once
the unit cools the fan will turn off�
For best efficiency the Room Air Fan should be left on at all times.
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
Figure 8: Room Air Fan Control.
NOTE: Some trim settings may cause undesirable operation with some fuels. Refer to “Fine
Tuning Your Pellet Stove” for more information.