Owner`s manual

7
PRe-buRn inStRuctionS
The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper
operation� Check the hopper for enough pellets to start the unit�
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to
be primed� This can be done by restarting the unit five (5) minutes into its start-up or by putting a small
hand full of pellets into the burnpot�
NEVER OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
automatic Safety featuReS of youR PeLLet Stove
A� EXHAUST TEMPERATURE SWITCH: The stove will shut off automatically if the exhaust temperature
drops below 49°C (120°F)�
B� HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93°C (200°F), the auger
will automatically stop and the stove will shut down when the exhaust temperature cools� If this
happens, call your local dealer to reset the 93°C (200°F) high limit switch�
IT IS IMPORTANT TO DETERMINE THE REASON THAT THE UNIT OVERHEATED.
C� VACUUM SWITCH: If the combustion fan fails or the exhaust vent becomes blocked this switch will
stop the auger feed motor and the fire will go out�
Operating Instructions
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
Figure 3: VF100 Control Panel
1. AUGER LIGHT: This green light will flash when the auger
pulses�
2. MODE LIGHT: This light will signal the current state of
the unit� If the light is flashing the unit is in automatic
start mode or the thermostat has control of the unit� Heat
settings cannot be changed� If the light is solid, the heat
level settings can be changed�
3. THERMOSTAT SWITCH: Sets the unit to one of the
two thermostat modes (High/Low or Auto/Off) or manual
operation mode�
4. FEED RATE TRIM BUTTON: Fine tuning control for
adjusting the feed� See “Adjusting Trim Settings�
5. COMBUSTION BLOWER TRIM BUTTON: Fine tuning
control for adjusting the combustion air flowSee Adjusting
Trim Settings�
7. ROOM AIR FAN ON/OFF BUTTON: Used to turn
convection fan on or off� See “Room Air Fan On/Off
8. HEAT LEVEL ADJUSTMENT BUTTONS: When pressed,
will change the heat level setting of the unit up or down�
9. HEAT OUTPUT INDICATOR: Shows the current heat
output setting�
the contRoL PaneL