Owner`s manual

5
ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be
grounded� The grounded electrical cord should be connected to a standard 115 volts (4�5 Amps), 60
hertz electrical outlet� Ensure that the polarity to the outlet that the unit will be plugged into is correct;
as incorrect polarity can adversely affect the unit’s operation� Be careful that the electrical cord is not
trapped under the appliance and that it is clear of any hot surfaces or sharp edges� The power cord
must always be accessible� If this power cord should become damaged, a replacement power cord must
be purchased from the manufacture or a qualified VistaFlame dealer The VF100’s maximum power
requirement is 520 watts�
GLASS: Do not abuse the glass by striking or slamming the door Do not attempt to operate the
stove with broken glass� The stove uses ceramic glass� Replacement glass must be purchased from a
VistaFlame dealer Do not attempt to open the door and clean the glass while the unit is in operation
or if glass is hot� To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove
glass cleaner, or take a damp paper towel and dip into the fly ash� This is a very mild abrasive and will
not damage the glass�
FLAMMABLE LIQUIDS: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter
fluid, or similar liquids to start or “freshen up” a fire in the heaterKeep all such liquids well away from
the heater while it is in use�
SMOKE DETECTOR: Smoke detectors should be installed and maintained in the structure when
installing and operating a pellet burning appliance�
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet
stove� Ensure all gaskets on the door are checked regularly and replaced when necessary
KEEP ASH PAN FREE OF RAW FUEL.
DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN� A fire in the ash pan may occur
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through
walls, ceilings, or roofs� It is recommended that the unit be secured into its position in order to avoid any
displacement�
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE�
FRESH AIR: Outside Fresh Air connection is optional, but must be connected to all units installed in
Mobile and Air Tight Homes” (R2000) or where required by local codes� Consider all large air moving
devices when installing your unit and provide room air accordingly� Limited air for combustion may result
in poor performance, smoking, and other side effects of poor combustion�
If you have any questions with regards to your stove or the above-mentioned information, please feel
free to contact your local dealer for further clarification and comments�
SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF
YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED
FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SHERWOOD
INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE