Owner`s manual
19
Air Supply Inlet
Gas Meter
Restriction Zone
(Termination not allowed)
Termination Cap
G
G
Opens
Opens
Opens
D
F
B
B
A
I
H
K
G
G
L
C
E
hot enough to cause burns if touched by children� Non-combustible shielding or guards may be required�
3� Termination must exhaust above the inlet elevation� It is recommended that at least five feet of vertical pipe be
installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the
possibility of smoke or odor during appliance shut down or power failure� This will keep exhaust from causing a
nuisance or hazard from exposing people or shrubs to high temperatures� In any case, the safest and preferred
venting method is to extend the vent through the roof vertically�
4� Distance from the bottom of the termination and grade is 12” (30 cm) minimum� This is conditional upon the
plants and nature of grade surface� The exhaust gases are hot enough to ignite grass, plants and shrubs located
in the vicinity of termination� The grade surface must not be lawn�
5� If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior
of the house might occur� Since these factors are beyond the control of Sherwood Industries Ltd, we grant no
guarantee against such incidents�
NOTE: Venting terminals shall not be recessed into walls or siding.
Installation
vent teRmination ReQuiRementS
IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER.
Figure 26: Use in conjunction with Table 1 for allowable exterior vent termination
locations.
Table 1: Use in conjunction with Figure 19 for allowable exterior vent termination locations.
Letter Minimum Clearance Description
A 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials�
B 48 in (122 cm) Beside/below any door or window that may be opened� (18” (46 cm) if outside
fresh air installed�)
C 12 in (30 cm) Above any door or window that may be opened� (9” (23 cm) if outside fresh air
installed�)
D 24 in (61 cm) To any adjacent building, fences and protruding parts of the structure�
E 24 in (61 cm) Below any eave or roof overhang
F 12 in (30 cm) To outside corner�
G 12 in (30 cm) To inside corner, combustible wall (vertical and horizontal terminations)�
H 3 ft (91 cm) within a height
of 15 ft (4�5 m) above the
meter/regulator assembly
To each side of center line extended above natural gas or propane meter/
regulator assembly or mechanical vent�
I 3 ft (91 cm) From any forced air intake of other appliance
J 12 in (30 cm) Clearance to non-mechanical air supply inlet to building, or the combustion air
inlet to any appliance�
K 24 in (61 cm) Clearance above roof line for vertical terminations�
L 7 ft (2�13 m) Clearance above paved sidewalk or paved driveway located on public property�
1� Do not terminate the
vent in any enclosed or
semi-enclosed areas such
as a carport, garage,
attic, crawlspace, narrow
walkway, closely fenced
area, under a sun deck
or porch, or any location
that can build up a
concentration of fumes
such as stairwells, covered
breezeway, etc�
2� Vent surfaces can become