Owner`s manual

18
cLeaRanceS to combuStibLeS - fReeStanDing
Figure 23: VF100 FS Clearance to Combustibles.
30"
(76cm)
48"
(122cm)
36"
(91cm)
Minimum Alcove width - 36 inches (91 cm)
Minimum Alcove height - 48 inches (122 cm)
Maximum Alcove depth - 30 inches (76 cm)
Figure 24: VF100 FS Alcove Size.
cLeaRanceS to aLcove - fReeStanDing
Figure 25: VF100 FPI Clearance to Combustibles.
Refer to Figure 15�
Side wall to unit - 8 inches (20�3 cm)
Mantel projection - 10 inches (25�4 cm)
Mantel to top of unit - 8 inches (20�3 cm)
Top facing to unit - 8 inches (20�3 cm)
Side facing to unit - 6 inches (15�2 cm)
Floor protection - 6 inches (15�2 cm)
On either side and to the front must be protected by
non-combustible material�
cLeaRanceS to combuStibLeS - inSeRt
Installation
6"
1"
1"
6"
Back Wall
Adjacent Wall
Floor
10
"
Min. 8"
(203mm)
Min. 8"
(203mm)
6" (152mm)
Side Wall
When installing this unit on a combustible floor (for
example linoleum, hardwood flooring) a non-combustible
hearth pad must be under the unit, unless installed as
shown on page 16� The pad must extend at least the
width of the appliance [22” (558 mm)] and at least the
depth of the appliance plus 6” (153 mm) in front of the
appliance [30½” (775 mm)]� A non-combustible hearth
pad must always be used if installing on carpet
Side wall to unit - 6 inches (15 cm)
Back wall to unit - 1 inches (2�5 cm)
Corner to unit - 1 inches (2�5 cm)
Door front to edge of floor protection
- 6 inches (15 cm)
NOTE: These dimensions are minimum clearances but
it is recommended that you ensure sufficient room for
servicing, routine cleaning and maintenance�