User manual
61
1. Move the mouse to Pre-Viewer window and then click the right button of the mouse. A new pop-
up menu window appears.
2. Click the New tab, and then configure, resize, and place the VMD area.
3. Click in the Windows title box and type a title (1 to 31 alphanumeric characters).
4. Adjust the Sensitivity, Threshold, and Motion dwell time setting values.
5. The VMD listed shows and their setting values also show every time if you select one of the lists.
6. Click the Save button to save the settings.
NOTES
- If you want to configure more VMD area, repeat above step.
- If you want to delete VMD area, select one of the Windows title listed and then click the Remove
button.
Windows title: Click in the Windows title box and type for a window’s title you are creating (1 to
31 alphanumeric characters).
Sensitivity: Ordinary colored objects on ordinary backgrounds will trigger motion detection.
NOTE
To only detect flashing light, select a low sensitivity. In other cases, a high sensitivity level is
recommended.
Threshold (Object Size): Only very large objects cause motion detection.
NOTE
To avoid triggering on small objects in the image, a high level can be selected. Set a low level to
also trigger for small objects.
Motion dwell time: Means how long time the alarm output signal hold on as an output signaling
source. The default setting is 60 seconds.
Enable down FPS: Click the Enable down FPS checkbox to enable for lower frame rate transmit
in normal state. The default setting is disabling.
- Click the Save button to save the settings, or click the Reset button to clear all of the information