User manual
0150-0319A 12 Vista Triplex
2
CDR/DVD
RS485 Connector
Wire Type: #24 AWG, twisted pair with shield
(2-wire)
Connector Type: RJ-45
Max. Cable Length: 3200 feet / 1000 meters
Shields are grounded at one end, preferably at the
Vista Triplex
2
CDR/DVD end.
See section 3.18 for information about configuring
the RS485 network address settings in the menu
system.
RJ-45 Pin Configuration For RS485 Port
Pin Use
Pin Use
1 Ground (Shield) 5 Not Connected
2 12Vdc +ve 6 Network -ve
3 Network +ve 7 Ground (Shield)
4 Not Connected 8 12Vdc +ve
82345671
RJ-45 socket on
back panel.
The 12Vdc power is used when connecting to the Vista NPX/RKB, if connecting multiple
Triplexes together the 12Vdc +ve must not be connected.
Ethernet Port
Wire Type: Cat 5
Connector Type: RJ-45
Max. Cable Length: 100 meters / 328 ft.
Min. Cable Length: 6 feet / 1.8 meters
Hub Wiring Configuration: Straight Through
PC Wiring Configuration: Cross Over
The cable connection configuration depends on your
network configuration:
• For a Vista Triplex
2
CDR/DVD that connects
directly to a Hub or Switch, use a straight through
connection.
• For a Vista Triplex
2
CDR/DVD that connects
directly to a PC, use a cross over connection.
Consult with your MIS personnel for the specific type
of configuration. See section 3.18 for information
about configuring the Ethernet settings in the menu
system.
RJ-45 Pin Configuration For Ethernet Port
Pin Use
Pin Use
1 TX+ 5 Not Connected
2 TX- 6 RX-
3 RX+ 7 Not Connected
4 Not Connected 8 Not Connected
82345671
RJ-45 socket on back
panel.